2 KVA - Off Grid Solar Inverter With In-Built Lithium Battery - 50/80/100Ah

S. No. Parameter Unit Rating
1Model name (2 KVA)2000
2System ratingVA2000 (1600 WATT)
3Battery Type (Inbuilt)Lithium Ion (Lifepo4)
4Battery ratingAH50/85/100
5Full load Input current ±2AAmp63
6Operating DC voltageV25.6
7Input voltage max VocVdc50
8Maximum Solar array powerWp1500
9Switching element in SCCMOSFET
10Type of controlMicro
11Type of solar chargerPWM
12Max current rating of SCCAdc70.0
13Efficiency of MPPT tracking%NA
14Efficiency of SCC%>90
15Switching element in InverterMOSFET
16Type of ControlPWM
17Nominal Output voltage in inverter modeVac220V ±7V
18Output supply phasessingle
19Nominal Output Frequency of InverterHz50 ±1
20Frequency (Min - Max during Grid by pass) UPS modeHz47-53
21Frequency (Min - Max during Grid by pass) Inverter modeHz40-60
22Output voltage regulation%180-220
23Output THD (w) at linear load%<3%
24Crest Factor03:01
25Overload capacity 125%Sec6 (6 Retry)
26Overload capacity 150%Sec2 (6 Retry)
27Cooling Fan ON at temp°C60 (or 45% of rated Load or Solar >15A)
28Cooling Fan OFF at temp°C55 (or 40% of rated Load or Solar <15A)
29Peak efficiency of inverter%<82
30Battery low voltage alarmVdc22.0 ±0.4
31Battery low voltage cut per batteryVdc21.6 ±0.4 (With 4 Retry)
32Battery cut recovery per battery through SolarVdc24.7 ±0.2 (or Mains or reset switch on front panel)
33Max Battery charging voltage by gridVdc28.4 ±0.4
34Max Battery charging current by gridAdc15±2A
35Max Battery charging voltage by SolarVdc28.0 ±0.4
36Battery High cut with AlarmVdc30.0±0.2
37Max Battery charging current by SolarAdc25±2A
38Max Charging current to battery by Solar+GridAdc25±2A
39Grid low cut voltage (T load/Normal load)Vac180/100 ±10
40Grid low cut voltage (T load/Normal load)Vac190/110 ±10
41Grid high cut voltage (T load/Normal load)Vac265/280 ±10
42Grid high cut voltage recovery (T load/Normal load)Vac255/270 ±10
43Grid charging Enable/Disableyes
44Selection of UPS Load/Normal Loadyes
45Input current at no load at Nominal Battery voltageAdc<2
46Noise @ 1 meterdB<50
47 Protections Overload, Battery Deep discharge, Battery Overcharge, Short circuit (retry), Battery Hi-PV Reverse, Over Temp, Fuse/MCB Trip, Battery reverse.
LCD Display parameters PV Current, Battery voltage, Mains voltage, UPS ON/OFF, UPS Mode, Symbol of sun (Smily) if solar available, (non smily symbol in absence of solar), Load percentage (0 to 150%), over load, short ckt, fault, battery low, over temp, PV reverse, Fuse trip (Customised LCD)
48Indication LEDsTact switch Status
49Operating Temperature range°C0-50
50Storage Temperature range°C0-65
51Max RH%95
52Front panel details (Display, Selection switch etc)Display with tact switch
53Enclosure protectionIP20
54Changeover time in UPS modems<10
55Changeover time in Normal mode (Inv mode)ms <40
56Input Protection Rated MCB
57Backup @ 400Watt LoadHrs 4.0–7.0
58Weight without PackingKg32–38
59Dimension (L×W×H) without PackingMM500×445×180