600 VA - On Grid Solar Inverter With In-Built Lithium Battery
S. No. Parameter Unit Rating
1Model name (600 VA)VA600
2System ratingVA600 / 480WATT
3Battery Type (inbuilt)AHLithium Ion (Lifepo4) 50/86/100
4Full Load Input Current 22AAmp45
5Operating DC voltageV12.8
6Input voltage maxVdc25
7Maximum Solar array powerWp660
8Switching element in SCCMOSFET
9Type of controllerMicro
10Type of solar chargerPWM
11Max current rating of SCCAdc40.0
12Efficiency of MPPT tracking%NA
13Efficiency of SCC%>90
14Switching element in inverterMOSFET
15Type of ControlPWM
16Nominal Output voltage in inverter modeVac220V ±7V
17Output supply phasessingle
18Nominal Output frequency of InverterHz50 ±1
19Frequency (Min - Max during Grid by pass) UPS modeHz47–53
20Frequency (Min - Max during Grid by pass) Inverter modeHz40–60
21Output voltage regulation%180–220
22Output THD (at linear load)%<5%
23Crest Factor03:01
24Overload capacity 125%Sec6 (6 Retry)
25Overload capacity 150%Sec2 (6 Retry)
26Cooling Fan ON at temp°C60 (or 45°C rated Load or Solar >15A)
27Cooling Fan OFF at temp°C55 (or 40% of rated Load or Solar <15A)
28Peak efficiency of inverter%<92
29Battery low voltage alarmVdc11.0 ±0.2
30Battery low voltage cutVdc10.2 (with 0.2C Retry)
31Battery low cut recovery per battery through SolarVdc12.7 ±0.2 (or Mains or reset switch on front panel)
32Max Battery charging voltage by gridVdc14.2 ±0.2
33Max Battery charging current by gridAdc15 ±2A
34Max Battery charging voltage by SolarVdc15.3 ±0.2
35Battery High cut with AlarmVdc15.0 ±0.2
36Max Battery charging current by SolarAdc15 ±2A
37Max Charging current to battery by Solar-GridAdc15 ±2A
38Grid low cut voltage (If load/Normal load)Vac180/100 ±10
39Grid low cut voltage recovery (If load/Normal load)Vac190/110 ±10
40Grid high cut voltage (If load/Normal load)Vac265/280 ±10
41Grid high cut voltage recovery (If load/Normal load)Vac255/270 ±10
42Grid charging Enable/Disableyes
43Selection of UPS Load/Normal Loadyes
44Input current at no load at Nominal Battery voltageAdc<2
45Noise @ 1 meterdB<50
46 Protections Overload, Battery Deep discharge, Battery Overcharge, Short circuit (retry), Battery HV, PV Reverse, Over Temp, Fuse/Mcb Trip, battery reverse
47 LCD Display parameters PV Current, Battery voltage, Mains voltage, UPS ON/OFF, UPS Mode, Symbol of sun (simily if solar available), Non simily if absence of solar, Load percentage (0 to 150%), Over load, short ckt, full battery, low battery, over temp, PV reverse, Fuse trip, (Customised LCD)
48Indication LEDsTact switch Status
49Operating Temperature range°C0–50
50Storage Temperature range°C0–45
51Max RH%95
52Front panel details (Display, Selection switch etc)Display with tact switch
53Enclosure protectionIP20
54Changeover time in UPS modems<10
55Changeover time in Normal mode (Inv mode)ms<40
56Input ProtectionResettable Circuit breaker
57Backup @ 400Watt LoadHrs2.00–3.25
58Weight without PackingKg18
59Dimensions (LXWXH) without PackingMM445x385x170